On a DC motor, A1 and A2 are the armature terminals. They connect to the rotating winding through the brushes, and they carry the main current. S1 and S2 mark a series field winding, if the motor has one. Many simple DC motors, including permanent-magnet types, have only A1 and A2. Labels vary between makers and standards, so the nameplate or datasheet is the final check.
Armature terminals: A1 and A2
The armature is the rotating winding. Current reaches it through the brushes and commutator, so the armature terminals carry the main power to the motor. Reversing the current through the armature reverses the direction of the torque.
A permanent-magnet DC motor has its magnets fixed to the frame, with no field winding. Such a motor has only the two armature terminals.
Field windings: S1 and S2
A field winding creates the magnetic field that the armature works against. In a series-wound motor, the field winding is connected in series with the armature, and it is marked S1 and S2. Series-wound motors give high starting torque, and their speed falls as the load rises.
Other motors use a shunt field or a separately excited field. Labels for these vary. A shunt field is often marked F1 and F2, but check the nameplate.
Label table
| Label | Usually means | Notes |
|---|---|---|
| A1, A2 | Armature (rotating winding) | Carries the main current. The only pair on a permanent-magnet motor. |
| S1, S2 | Series field winding | In series with the armature. Gives high starting torque. |
| F1, F2 | Shunt field (common marking) | Do not disconnect it while the motor is running. |
Larger DC machines may also have interpole or compensating windings, which help the commutation. Their labels vary too, so use the datasheet for those.
How to reverse a DC motor with these terminals
To reverse a DC motor with field windings, reverse the current through either the armature or the field, not both. Reversing both leaves the direction unchanged.
For a permanent-magnet motor, swap A1 and A2.
Unlabelled motors: testing safely
If the labels have worn off and there is no datasheet:
- Use a multimeter on resistance to find the pairs of leads. Each winding shows up as a pair with a measurable resistance.
- Do not assume which pair is which. Work out the motor type first. A permanent-magnet motor has no field pair.
- Test with a current-limited supply at low voltage, and watch the current. Do not connect an unknown motor to full supply voltage.
- Do not open or disconnect a shunt field while the motor is running. A broken shunt field can let the motor overspeed dangerously.
For how a DC motor’s speed and torque respond to voltage, see DC motor speed control using PWM. For reversing with an H-bridge, see how to reverse a DC motor with an H-bridge.