What an RLC circuit is
A series RLC circuit has a resistor (R), an inductor (L) and a capacitor (C) in one loop, driven by an AC source. “LCR circuit” means the same thing. Parallel RLC circuits also exist, but the series form is the usual starting point.
Reactance and impedance
In AC circuits, inductors and capacitors oppose current in a way that depends on frequency:
- Inductive reactance: XL = 2πfL, in ohms
- Capacitive reactance: XC = 1 / (2πfC), in ohms
- Impedance: Z = √(R² + (XL − XC)²), in ohms
- Phase angle: tan φ = (XL − XC) / R
The RMS current is I_rms = V_rms / Z. If XL is greater than XC, the circuit is inductive, and the voltage leads the current by φ. If XC is greater than XL, the circuit is capacitive, and the current leads.
Resonance
When XL = XC, the two reactances cancel. The impedance is then just R, the current is at its largest for the given source, and the voltage and current are in phase. The resonant frequency is:
f0 = 1 / (2π√(LC))
Worked example at resonance
Take R = 10 Ω, L = 10 mH (0.01 H), C = 100 µF (0.0001 F), and a 10 V rms source.
- Resonant frequency: f0 = 1 / (2π × √(0.01 × 0.0001)) = 1 / (2π × 0.001) ≈ 159 Hz
- Reactances at f0: XL = 2π × 159 × 0.01 ≈ 10 Ω, and XC = 1 / (2π × 159 × 0.0001) ≈ 10 Ω. They cancel.
- Impedance: Z = R = 10 Ω
- Current: I_rms = 10 V / 10 Ω = 1 A
- Phase angle: φ = 0
Power in an RLC circuit
Only the resistor dissipates power on average. The inductor and capacitor store energy and return it every cycle, so their average power is zero. The average (real) power is:
P = V_rms × I_rms × cos φ
This can also be written as P = I_rms² × R, since cos φ = R / Z.
At resonance, P = 10 V × 1 A × cos 0° = 10 W, which matches I²R = 1² × 10 = 10 W.
Two related quantities complete the picture:
- Apparent power: S = V_rms × I_rms, in volt-amperes (VA)
- Reactive power: Q = V_rms × I_rms × sin φ, in volt-amperes reactive (VAR)
The power factor is cos φ = P / S.
Off-resonance example. Suppose a load draws 2 A rms from a 120 V rms supply, with a phase angle of 60°. Then P = 120 × 2 × cos 60° = 120 W. S = 240 VA, Q = 240 × sin 60° ≈ 208 VAR, and the power factor is 0.5. The real power is only half the apparent power, which is why a low power factor means more current for the same useful power.
Step-by-step method
- Compute XL and XC at the source frequency.
- Compute Z and φ from R, XL and XC.
- Compute the current: I_rms = V_rms / Z.
- Find the voltage across each element: V_R = I × R, V_L = I × XL, V_C = I × XC. These do not add as plain numbers, because they are out of phase. Add them as phasors.
- Find the average power: P = V_rms × I_rms × cos φ.
The voltage across the inductor or capacitor can be larger than the source voltage when R is small compared with the reactances. In the resonance example, each reactive voltage is 10 V, equal to the source, and they cancel in the phasor sum.
Common mistakes
- Mixing peak and RMS values. Use RMS values consistently in P = V_rms × I_rms × cos φ.
- Adding voltages across R, L and C as plain numbers. Use phasors, because the elements are out of phase.
- Forgetting the phase. Check whether XL is greater or less than XC before you decide whether the circuit is inductive or capacitive.
- Calling reactive power “lost”. It is stored and returned each cycle. It does not contribute to average power.
Next steps
- For the transient, DC-only case with a capacitor, see Solving Circuits With Capacitors and Resistors.
- For watts, volt-amperes and the units behind them, see Electrical Power in a Circuit.
- For the general starting point, see Circuit Analysis Basics.