What Kirchhoff’s laws say
Gustav Kirchhoff set out two rules in the 1840s. They are the basis of most hand analysis of resistor networks, and they apply to AC circuits too, with impedances in place of resistances.
- Kirchhoff’s current law (KCL): The sum of the currents entering a node (a junction) equals the sum of the currents leaving it. Equivalently, the signed sum of the currents at a node is zero. This follows from conservation of charge.
- Kirchhoff’s voltage law (KVL): Going around any closed loop, the voltage rises and drops add up to zero. This follows from conservation of energy.
KCL in practice
Take a node where a 12 V source feeds two resistors in parallel: 6 Ω and 3 Ω.
- Current through the 6 Ω branch: 12 V / 6 Ω = 2 A
- Current through the 3 Ω branch: 12 V / 3 Ω = 4 A
- Total current leaving the source: 2 A + 4 A = 6 A
At the top node, the current entering is 6 A, and the currents leaving are 2 A and 4 A. KCL holds: 6 A in equals 6 A out.
If a current comes out negative when you solve, it flows opposite to the arrow you drew. That is not an error. It means the arrow was the wrong way round.
KVL in practice
Now take a single loop: a 12 V source in series with R1 = 2 Ω and R2 = 4 Ω.
- Loop current: I = 12 V / (2 Ω + 4 Ω) = 2 A
- Voltage across R1: 2 A × 2 Ω = 4 V
- Voltage across R2: 2 A × 4 Ω = 8 V
Going around the loop: +12 V (source rise) − 4 V − 8 V = 0. KVL holds.
Solving a circuit with both laws
- Label every branch current with an arrow. Any direction works. The sign of the answer will tell you if the guess was wrong.
- Mark resistor polarities so that the current enters the + side of each resistor. Then the voltage drop follows the current.
- Write KCL at every node except one reference node.
- Write KVL around enough loops to give as many independent equations as you have unknown currents.
- Solve the system, then check that the power supplied equals the power dissipated.
Larger networks follow the same logic. Circuit simulators solve the same equations in matrix form.
Common mistakes
- Mixing up current direction and voltage polarity. Keep the passive sign convention: current into the + terminal of a resistor means a voltage drop in the direction of the current.
- Missing a branch when writing KCL at a node.
- Losing track of sign in KVL. Going from − to + through a source is a rise. Going through a resistor in the direction of the current is a drop.
- Treating an open switch as having zero voltage. An open switch can have a voltage across it, and KVL must include that voltage.
Limits of the laws
The laws assume the lumped-element model. Components are treated as ideal, and the wires are assumed to have no voltage across them. At very high frequencies, or where a changing magnetic field induces voltage around a loop, the laws lose accuracy. Radio-frequency and high-speed circuits may need transmission-line analysis.
Where these laws are used next
- The voltage divider formula is KVL and Ohm’s law applied in one step.
- Thevenin’s theorem starts by finding an open-circuit voltage, which uses both laws.
- Superposition lets you apply the laws to one source at a time.
- For the broader picture, start with Circuit Analysis Basics.