What Thevenin’s theorem says
Any linear network of sources and resistors, seen from two terminals, can be replaced by a single voltage source V_th in series with a single resistance R_th. From the load’s point of view, the two circuits behave the same. The load sees the same voltage and the same current in both, for any load value.
The Norton equivalent is the same idea in a different form: a current source I_N in parallel with a resistance R_N, where R_N = R_th. It is covered below.
Steps
- Remove the load from the two terminals you want to study.
- Find V_th, the open-circuit voltage across those terminals. Use Ohm’s law, voltage division or Kirchhoff’s laws.
- Find R_th. Turn off the independent sources: replace each ideal voltage source with a short circuit, and each ideal current source with an open circuit. Then find the resistance seen from the terminals.
- Build the equivalent. Draw V_th in series with R_th, and reconnect the load across the output terminals.
- Solve for the load current or voltage, and check the answer.
When there are dependent sources
Do not turn off dependent sources. Instead, find V_th as before, then find the short-circuit current I_sc by connecting a short across the terminals. Then:
R_th = V_th / I_sc
Worked example
A 12 V source sits in series with R1 = 4 Ω, feeding a node called A. From node A to ground is R2 = 6 Ω. A load RL connects from node A to ground, in parallel with R2. Find the load current when RL = 4.8 Ω.
Step 1: V_th. With the load removed, the 4 Ω and 6 Ω resistors carry 12 V / (4 Ω + 6 Ω) = 1.2 A. The voltage at node A is 1.2 A × 6 Ω = 7.2 V. So V_th = 7.2 V.
Step 2: R_th. Short the 12 V source. The 4 Ω resistor now connects node A to ground, in parallel with R2. R_th = 4 Ω ∥ 6 Ω = (4 × 6) / (4 + 6) = 2.4 Ω.
Step 3: Load current. The equivalent is 7.2 V in series with 2.4 Ω, feeding the 4.8 Ω load:
I_L = 7.2 V / (2.4 Ω + 4.8 Ω) = 1.0 A, so V_L = 4.8 V.
Check against the original circuit. The load and R2 are in parallel: 6 Ω ∥ 4.8 Ω ≈ 2.67 Ω. The total resistance is 4 Ω + 2.67 Ω ≈ 6.67 Ω, so the source current is 12 V / 6.67 Ω = 1.8 A. The voltage at node A is 1.8 A × 2.67 Ω ≈ 4.8 V. The load current is 4.8 V / 4.8 Ω = 1.0 A. The two methods agree.
Norton equivalent
The Norton equivalent of the same network has:
- I_N = V_th / R_th = 7.2 V / 2.4 Ω = 3 A
- R_N = R_th = 2.4 Ω, in parallel with I_N
The load current is 3 A × 2.4 Ω / (2.4 Ω + 4.8 Ω) = 1.0 A, the same as before.
Maximum power transfer
For a fixed source, the load receives the most power when R_L = R_th. The maximum power is:
P_max = V_th² / (4 × R_th)
In the example, R_L = 2.4 Ω gives I = 7.2 V / 4.8 Ω = 1.5 A and P = 1.5² × 2.4 = 5.4 W. Half of the source’s power is lost in R_th at this point, so this is not an efficient operating point. It is the right choice when you want the most power delivered to a load, not the most efficient one.
When to use it, and its limits
Thevenin’s theorem is most useful when one part of a circuit changes often, such as a sensor or a load you are testing. You analyze the source side once, then reuse the equivalent for each load value.
Its limits matter:
- It applies to linear circuits only.
- The equivalence holds at the two terminals. The power dissipated inside the original network is not the same as inside the equivalent.
For the rules used in the steps, see Kirchhoff’s Voltage and Current Laws. For a related method that handles multiple sources, see Superposition Theorem. For a simple divider as a Thevenin source, see Voltage Divider Formula With Worked Examples.