Types of power converters
A power converter changes voltage, current or the form of electrical power. Converters fall into four families:
| Type | Input to output | Examples |
|---|---|---|
| AC-DC | AC to DC | Rectifiers, mains adapters, power supplies |
| DC-AC | DC to AC | Inverters, which take battery power and make AC |
| DC-DC | DC to DC at a different voltage | Buck, boost, buck-boost |
| AC-AC | AC to AC at a different voltage or frequency | Transformers, cycloconverters |
Most power supplies you buy combine more than one family. A mains adapter is an AC-DC converter, and many also have a DC-DC stage inside.
What a DC-DC converter is called
A DC-to-DC converter is usually just called a DC-DC converter. Within that group:
- A buck converter steps the voltage down.
- A boost converter steps the voltage up.
- A buck-boost converter can do either. In its basic form it also inverts the polarity of the output.
Switching DC-DC converters use a transistor and an inductor to move energy in small packets. Linear regulators can only step down, and they waste the difference as heat, as explained in DIY linear power supply circuits.
What is a dual converter?
In power electronics, a “dual converter” usually means two converter bridges connected back to back in opposite directions. This lets current flow both ways, which is useful in motor drives. Outside that setting, the term is rarely used.
Buck, boost and buck-boost at a glance
These relations assume ideal parts with no losses, and that the inductor current never falls to zero. D is the duty cycle, the fraction of each switching period that the switch is on.
| Converter | Output versus input (ideal) | Notes |
|---|---|---|
| Buck | Vout = D × Vin | Output is always lower than the input |
| Boost | Vout = Vin / (1 − D) | D must be below 1; output is always higher |
| Buck-boost | |Vout / Vin| = D / (1 − D) | Output polarity is inverted in the basic form |
Calculating a boost converter’s power stage
Take a worked example: input 12 V, output 24 V, load current 1 A, switching at 100 kHz, inductor 100 µH.
Step 1: Duty cycle. D = 1 − Vin / Vout = 1 − 12 / 24 = 0.5.
Step 2: Average inductor current. IL = Iout / (1 − D) = 1 A / 0.5 = 2 A. In a boost, the input current equals the inductor current.
Step 3: Inductor ripple (peak to peak). ΔIL = (Vin × D) / (L × fsw) = (12 × 0.5) / (100 × 10⁻⁶ × 100 × 10³) = 6 / 10 = 0.6 A.
Step 4: Power check. Output power is 24 V × 1 A = 24 W. With no losses, input power is also 24 W, so the input current is 24 W / 12 V = 2 A. This matches Step 2, which is a useful check on your working.
For the inductor, the peak current is the average plus half the ripple: 2 A + 0.3 A = 2.3 A. Choose an inductor whose saturation current is comfortably above that figure.
Real converters lose power in the switch, the diode, the inductor and the capacitors. The real input current is therefore higher than the ideal 2 A. These formulas are for a first estimate. A real design also needs component ratings, a loss budget, a control loop and testing.
Common mistakes
- Using the buck formula for a boost. This gives an output lower than the input, which is wrong for a boost.
- Choosing an inductor that is too small. The ripple gets large and the inductor can saturate.
- Forgetting that a boost converter has no protection against a shorted output. The output is connected to the input through the inductor and diode, so a short can draw a large current. Put a fuse on the input and test at low voltage with a current limit.
DC link capacitor sizing
A DC link is the capacitor, or bank of capacitors, on the DC bus between a rectifier and an inverter. It is common in motor drives and inverter systems. Its job is to hold the bus voltage steady and to supply the ripple current the inverter draws.
The energy the capacitor stores is:
E = ½ × C × (V2² − V1²)
Here E is the energy released when the voltage drops from V1 to V2. For example, a 470 µF capacitor at 400 V stores about ½ × 470 × 10⁻⁶ × 400², which is about 37.6 J.
There is no single formula for the final choice. Sizing depends on the ripple current the capacitor must handle, the hold-up time the application needs, and the ripple rating given by the manufacturer. Use the inverter’s specifications and the capacitor datasheet.
Warning: DC link voltages can be hundreds of volts. The capacitors keep a dangerous charge after power is removed. Discharge them with a suitable resistor before touching anything, and do not experiment with these voltages without proper training.
Safety when building converters
- Test at low voltage first, with a current limit set.
- Fuse the input.
- Keep your hands and probes away from the switching node, which has fast, high-voltage edges.
- Check the output before you connect a load.
Where this fits
Linear regulators can only step down, and they waste power as heat. Switching converters are more efficient, but they bring the noise and complexity covered in what the disadvantages of SMPS are. For simple voltage raising from a battery, see simple voltage boosting circuits, which covers why those circuits are limited. For an overview, see DC power supplies explained.