Capacitors

How to Test a Capacitor With a Multimeter

How to test a capacitor with a multimeter: discharge and isolate it, check capacitance mode, use resistance mode for a charging check, and read the results.

On this page
  1. Safety first
  2. What a multimeter can and cannot tell you
  3. Method 1: capacitance mode
  4. Method 2: resistance mode (charging check)
  5. What the readings mean
  6. Limits of a basic multimeter
  7. When to use a dedicated ESR or LCR meter
  8. Key takeaways

Safety first

Before you test anything, take these steps:

  1. Power off the equipment and unplug it. For a device on mains, switch off the breaker if the device cannot be unplugged.
  2. Discharge the capacitor. A capacitor can keep a charge after power is removed. Use a resistor rated for the energy involved, and check with a meter that the voltage has fallen to near zero before you touch the leads. Avoid a bare screwdriver across the terminals of a larger part, because it can spark and damage the capacitor. See how to discharge a capacitor faster.
  3. Isolate the part. Disconnect at least one leg, so the rest of the circuit does not change the reading.

High-voltage parts, such as camera flash capacitors and AC motor run capacitors, can hold a dangerous charge. If you are not trained to handle them, leave them to a qualified technician.

What a multimeter can and cannot tell you

A basic multimeter can show:

  • whether the capacitor is open, shorted or roughly within range of its marked value
  • whether a capacitor charges, in resistance mode

It cannot reliably show:

  • the equivalent series resistance (ESR), which rises as an electrolytic ages
  • the leakage current in detail
  • the behavior at the frequencies the circuit uses

A capacitor can fail in ways a basic meter misses, so a good reading does not prove the part is fine.

Method 1: capacitance mode

If your meter has a capacitance setting, use it:

  1. Set the dial to the capacitance symbol, or to the µF or nF range that covers the part’s value.
  2. Plug the black probe into COM and the red probe into the capacitance input. Check the meter’s manual, because the input socket varies by model.
  3. Touch the probes to the capacitor’s terminals. For a polarized part, touch red to positive and black to negative.
  4. Wait a few seconds for the reading to settle.

Reading the result against the marked value

Compare the reading with the marked value and tolerance. A part with a 10% tolerance should read within about 10% of its mark. Electrolytics often have a looser tolerance, such as ±20%, so a reading that is off by a fair amount may still be normal.

Polarized parts

Connect electrolytics and tantalum capacitors with the correct polarity, as described in capacitor polarity. Reverse connection can harm a polarized part, and the meter’s test voltage is low but not zero, so match the polarity even though the test is small.

Method 2: resistance mode (charging check)

If the meter has no capacitance range, a resistance check gives a rough pass or fail:

  1. Set the meter to a high resistance range, such as the kΩ or MΩ range.
  2. Touch the probes across the terminals.
  3. Watch the reading.

A good capacitor starts with a low reading and climbs as it charges from the meter’s internal battery, until the meter shows “OL” (overload) or a very high value.

What the readings mean

Reading Likely meaning
Capacitance close to the marked value Probably good
Capacitance far below the marked value, or zero Weak, dried out or open
Capacitance over-range on a large part The meter’s range is too small; use a range that fits
Resistance: starts low, climbs to OL Charging normally, probably good
Resistance: stays near 0 Ω Shorted
Resistance: OL immediately, no movement Open, or the part is not connected

Limits of a basic multimeter

ESR and why it matters

ESR is the internal resistance of a capacitor. In an electrolytic, ESR rises as the electrolyte dries out, and a rising ESR can cause problems in a power supply long before the capacitance drops much. A basic multimeter does not measure ESR, so a capacitor can pass a capacitance check and still be failing. For more on this, see ESR in capacitors.

In-circuit readings

A reading taken with the capacitor still in the circuit can be misleading, because other components give a parallel path. Desolder at least one leg to get a true reading.

When to use a dedicated ESR or LCR meter

If you work on power supplies or any electrolytic-heavy board, a dedicated ESR meter or LCR meter gives more useful information. These meters can check ESR and, in many cases, more accurate capacitance, and some can test in circuit. They are a better choice than a basic multimeter for electrolytics in switching supplies.

Key takeaways

  • Power off, discharge, and isolate the capacitor before testing.
  • In capacitance mode, compare the reading with the marked value and its tolerance.
  • In resistance mode, a good capacitor starts low and climbs toward OL as it charges.
  • A basic multimeter cannot measure ESR, so a passing reading does not prove the part is good.
  • For power supplies, a dedicated ESR or LCR meter is more informative.

For what a bad capacitor looks like before you test it, see signs a capacitor is bad.

The complete guide to capacitors

Capacitors Explained: How They Behave in DC and AC Circuits
Read the guide

Keep exploring

Guides from other topics

All topics →