Safety first
Before you test anything, take these steps:
- Power off the equipment and unplug it. For a device on mains, switch off the breaker if the device cannot be unplugged.
- Discharge the capacitor. A capacitor can keep a charge after power is removed. Use a resistor rated for the energy involved, and check with a meter that the voltage has fallen to near zero before you touch the leads. Avoid a bare screwdriver across the terminals of a larger part, because it can spark and damage the capacitor. See how to discharge a capacitor faster.
- Isolate the part. Disconnect at least one leg, so the rest of the circuit does not change the reading.
High-voltage parts, such as camera flash capacitors and AC motor run capacitors, can hold a dangerous charge. If you are not trained to handle them, leave them to a qualified technician.
What a multimeter can and cannot tell you
A basic multimeter can show:
- whether the capacitor is open, shorted or roughly within range of its marked value
- whether a capacitor charges, in resistance mode
It cannot reliably show:
- the equivalent series resistance (ESR), which rises as an electrolytic ages
- the leakage current in detail
- the behavior at the frequencies the circuit uses
A capacitor can fail in ways a basic meter misses, so a good reading does not prove the part is fine.
Method 1: capacitance mode
If your meter has a capacitance setting, use it:
- Set the dial to the capacitance symbol, or to the µF or nF range that covers the part’s value.
- Plug the black probe into COM and the red probe into the capacitance input. Check the meter’s manual, because the input socket varies by model.
- Touch the probes to the capacitor’s terminals. For a polarized part, touch red to positive and black to negative.
- Wait a few seconds for the reading to settle.
Reading the result against the marked value
Compare the reading with the marked value and tolerance. A part with a 10% tolerance should read within about 10% of its mark. Electrolytics often have a looser tolerance, such as ±20%, so a reading that is off by a fair amount may still be normal.
Polarized parts
Connect electrolytics and tantalum capacitors with the correct polarity, as described in capacitor polarity. Reverse connection can harm a polarized part, and the meter’s test voltage is low but not zero, so match the polarity even though the test is small.
Method 2: resistance mode (charging check)
If the meter has no capacitance range, a resistance check gives a rough pass or fail:
- Set the meter to a high resistance range, such as the kΩ or MΩ range.
- Touch the probes across the terminals.
- Watch the reading.
A good capacitor starts with a low reading and climbs as it charges from the meter’s internal battery, until the meter shows “OL” (overload) or a very high value.
What the readings mean
| Reading | Likely meaning |
|---|---|
| Capacitance close to the marked value | Probably good |
| Capacitance far below the marked value, or zero | Weak, dried out or open |
| Capacitance over-range on a large part | The meter’s range is too small; use a range that fits |
| Resistance: starts low, climbs to OL | Charging normally, probably good |
| Resistance: stays near 0 Ω | Shorted |
| Resistance: OL immediately, no movement | Open, or the part is not connected |
Limits of a basic multimeter
ESR and why it matters
ESR is the internal resistance of a capacitor. In an electrolytic, ESR rises as the electrolyte dries out, and a rising ESR can cause problems in a power supply long before the capacitance drops much. A basic multimeter does not measure ESR, so a capacitor can pass a capacitance check and still be failing. For more on this, see ESR in capacitors.
In-circuit readings
A reading taken with the capacitor still in the circuit can be misleading, because other components give a parallel path. Desolder at least one leg to get a true reading.
When to use a dedicated ESR or LCR meter
If you work on power supplies or any electrolytic-heavy board, a dedicated ESR meter or LCR meter gives more useful information. These meters can check ESR and, in many cases, more accurate capacitance, and some can test in circuit. They are a better choice than a basic multimeter for electrolytics in switching supplies.
Key takeaways
- Power off, discharge, and isolate the capacitor before testing.
- In capacitance mode, compare the reading with the marked value and its tolerance.
- In resistance mode, a good capacitor starts low and climbs toward OL as it charges.
- A basic multimeter cannot measure ESR, so a passing reading does not prove the part is good.
- For power supplies, a dedicated ESR or LCR meter is more informative.
For what a bad capacitor looks like before you test it, see signs a capacitor is bad.