Two rules: what is shared and what adds up
When you connect capacitors together, the wiring decides two things: what the parts share, and how their values combine.
- Parallel: every capacitor sees the same voltage. Capacitance adds.
- Series: every capacitor carries the same charge. Capacitance combines by the reciprocal rule, so the total is always smaller than the smallest part.
Inductors follow the opposite rules, which is covered at the end of this article.
Capacitors in parallel
Parallel capacitors connect to the same two nodes, so each one has the same voltage across it. Each capacitor stores charge in proportion to its own value (Q = C × V), so the larger parts take more of the total charge.
The total capacitance is the sum:
C_total = C1 + C2 + C3 + …
For example, 0.1 µF, 0.2 µF and 0.3 µF in parallel give 0.6 µF.
Parallel banks are common in power supplies. A large electrolytic is often paired with a smaller ceramic, so the bank filters both slow and fast ripple. Adding parts in parallel does not raise the voltage rating, which is discussed below.
Capacitors in series
In a series string, charge cannot cross the gap in a capacitor, so each capacitor ends up with the same charge. The voltage divides between them, and the smallest capacitor takes the largest share of the voltage.
The equivalent capacitance follows the reciprocal rule:
1 / C_total = 1 / C1 + 1 / C2 + 1 / C3 + …
Invert the sum to get the answer. For two parts, the shortcut is C_total = (C1 × C2) / (C1 + C2).
How to calculate capacitance in series
For two 470 µF capacitors in series:
C_total = (470 × 470) / (470 + 470) = 235 µF
For three 100 µF capacitors in series, the total is about 33 µF. The total drops with each part added, which is the main cost of series wiring.
Mixed networks: reduce step by step
Most real circuits mix series and parallel groups. The method is the same each time:
- Find the innermost group that is purely series or purely parallel.
- Reduce that group to one equivalent capacitor.
- Replace the group with that value and repeat.
- Stop when one equivalent capacitor remains.
Once you have the total, you can work backward for each part’s voltage and charge, if the source voltage is known. Total charge is Q = C_total × V_source.
Voltage ratings in series and parallel
Voltage ratings do not combine the same way as capacitance:
- Parallel: the bank is limited by its lowest-rated part. A 16 V capacitor in parallel with a 50 V capacitor should be treated as a 16 V bank.
- Series: the string can take more voltage in total, but the voltage divides unevenly. Small differences in leakage or tolerance can push one part above its rating.
Electrolytic capacitors in a series string are often balanced with resistors across each part, so the voltage divides more evenly. The balancing values depend on the leakage of the parts and the design, so follow the design’s guidance rather than a general formula. Do not assume that two 50 V parts in series give a safe 100 V bank without balancing.
Inductors work the other way round
Inductors combine by the opposite rules:
- Series: inductances add, L_total = L1 + L2 + …
- Parallel: the reciprocal rule applies, 1 / L_total = 1 / L1 + 1 / L2 + …
In an LC circuit, the two parts exchange energy. The resonant frequency is f = 1 / (2π√(LC)). A series RLC circuit passes signals most easily at its resonant frequency, while a parallel LC arrangement blocks it. This is why LC circuits are used as tuned filters in radio and audio.
Practical cautions
- Pre-charge before connecting. Connecting a charged capacitor directly to an uncharged one causes a large current surge and loses energy. Charge the new part through a resistor, or use the design’s charging circuit.
- Check tolerance. Electrolytic parts can vary by ±20% or more, so a computed total is an estimate.
- Check voltage at each step. Confirm that no part exceeds its rating, including during power-on transients.
Key takeaways
- In parallel, capacitance adds and every part sees the same voltage.
- In series, the reciprocal rule applies, the total is smaller than the smallest part, and the charge is the same on each part.
- A parallel bank is limited by its lowest-rated part.
- Series strings of electrolytics need balancing before they can be trusted.
- Inductors follow the opposite rules to capacitors.
For a quick answer on why parallel capacitors share a voltage, see does a parallel circuit have the same voltage. For voltage margin on a single part, see capacitor replacement guide.