Capacitors

Signs a Capacitor Is Bad: Bulging, Leaking and Failed Tests

How to tell a capacitor is bad: bulging or leaking cases, burn marks, motor and appliance symptoms, and multimeter results that point to a failed part.

On this page
  1. The quick answer
  2. Visual signs
  3. Electrical symptoms in motors and appliances
  4. Test it: a quick check
  5. A capacitor can look fine and still fail
  6. What to do next
  7. Key takeaways

The quick answer

A capacitor is probably bad if it is visibly damaged (bulging, leaking, burned or cracked), if it reads far from its marked value on a capacitance meter, or if it shows a dead short. Symptoms in the equipment also point to a capacitor, such as a motor that hums without starting. None of these signs proves the cause on its own, so check the rest of the circuit too.

Always discharge a capacitor before you touch it. See how to discharge a capacitor faster.

Visual signs

Look at the part with the power off and the capacitor discharged:

  • Bulging or swelling: a domed, split or “mushroomed” top, usually on an aluminum electrolytic. Internal pressure builds up when the part overheats or is subjected to overvoltage.
  • Leaking: oily or crusty residue around the terminals, the seal or the base. Electrolyte leaks are a clear sign of a failed electrolytic.
  • Burn marks or a smell: scorching, melted plastic or a burnt odor. Something has overheated.
  • Cracks: a visible crack in a ceramic disc or chip, often from board flex or heat stress.
  • Corrosion: green or white deposits on the leads or terminals, which can add resistance and cause intermittent faults.

Ceramic capacitors seldom bulge. A failed ceramic usually shows as a short or a crack, so a clean-looking ceramic can still be bad.

Electrical symptoms in motors and appliances

A capacitor can cause symptoms that look like something else. Common signs are below, and they are not proof on their own.

Air conditioners, fans and pumps

In AC equipment, a weak or dead run or start capacitor often causes:

  • a motor that hums or buzzes when powered but does not start or spin
  • a slow or hard start, or a motor that needs a push to start
  • overheating, thermal shutoffs, or a unit that shuts off soon after starting
  • weak cooling or sluggish fan speed

These parts store energy at mains voltage, even after the equipment is unplugged. Handle them with care, and leave the replacement to a technician if you are not trained for it.

Power supplies and electronics

In electronics, a failing electrolytic can cause:

  • a power supply with unstable or noisy output, or ripple on the rail
  • a device that resets, restarts or runs hot
  • hum in audio equipment
  • a board that works when cold and fails when warm

These symptoms can come from many parts, so a capacitor is one suspect among several. A rising ESR is a common cause of these faults in old electrolytics.

Test it: a quick check

  1. Power off and discharge. Confirm the voltage is near zero with a meter.
  2. Isolate the part. Disconnect at least one leg, so other components do not affect the reading.
  3. Capacitance check. If the meter has a capacitance range, compare the reading with the marked value and tolerance. A reading far below the label, near zero, or open suggests a bad part.
  4. Resistance check. Without a capacitance setting, use a high resistance range. A good capacitor starts low and climbs toward OL as it charges. A reading that stays near 0 Ω suggests a short.

For the full procedure, including the limits of a basic meter, see how to test a capacitor with a multimeter.

A capacitor can look fine and still fail

Some capacitors fail without any visible sign. An electrolytic can keep its capacitance while its ESR rises enough to cause heating or ripple. A film or ceramic part can open or short inside. A basic capacitance check may not catch either fault.

If the symptoms point to a capacitor and the part looks normal, consider an ESR or LCR meter, or replace it on the evidence of the symptoms and the circuit.

What to do next

  • Replace a bad part with one that matches the original. Check capacitance, voltage rating, type and size. See capacitor replacement guide.
  • Look for the cause. Overvoltage, heat, a bad regulator, or a failed part nearby can kill a new capacitor quickly.
  • Check polarity. Electrolytics must go in the right way round. See capacitor polarity.
  • Call a technician for mains equipment if you are not trained to work on it.

Key takeaways

  • Bulging, leaking, burn marks and cracks are clear signs of a bad capacitor.
  • In motors and appliances, a humming motor that will not start is a common capacitor symptom.
  • A capacitor can look normal and still fail, especially through rising ESR or an internal short.
  • A capacitance meter that reads far from the label, or shows a dead short, points to a bad part.
  • Replace the part, but look for the cause of the failure too.

The complete guide to capacitors

Capacitors Explained: How They Behave in DC and AC Circuits
Read the guide

Keep exploring

Guides from other topics

All topics →