What leakage current is
A capacitor is not a perfect insulator between its plates. A very small direct current always flows through the dielectric once a voltage is applied. This is called leakage current.
It is usually small, often in the nanoamp to microamp range, but it matters in circuits that need to hold a charge or carry very little current.
Modeling leakage as insulation resistance
Leakage can be modeled as a very high resistance, the insulation resistance (R_iso), in parallel with an ideal capacitor:
I_leak = V / R_iso
For example, 10 V across 100 MΩ gives I = 10 / 100,000,000 = 0.1 µA. The higher the insulation resistance, the smaller the leakage.
How leakage varies by capacitor type
- Electrolytic and tantalum: these typically leak more. Their datasheets often give a maximum leakage value, measured after a set time, so the oxide layer has time to stabilize.
- Ceramic and film: these usually leak much less. Their datasheets often give insulation resistance in megohms or gigohms, or a CR product in MΩ·µF, which describes the time constant of the leakage.
For a circuit that depends on low leakage, a ceramic or film part is usually the better choice. See tantalum vs electrolytic capacitors for how the electrolytic types compare.
Datasheet leakage figures
Electrolytic datasheets often specify a maximum leakage current as a formula based on the capacitance and voltage, such as I_leak ≈ k × C × V. The constant k and the form of the formula vary by manufacturer and part, so use the figure for the part you are using. The figure is usually given after a set time, often a few minutes, because the leakage falls over the first minutes after voltage is applied.
Ceramic and film datasheets give insulation resistance or a CR product instead. A high CR product means low leakage, and it is a good figure to compare when choosing a part.
What raises leakage
- Higher voltage: leakage rises as the applied voltage approaches the rating.
- Higher temperature: heat increases the conduction through the dielectric.
- Thinner dielectric or smaller packages: these can have lower insulation resistance.
- Aging or storage: an electrolytic that has been stored for a long time may show higher initial leakage, and a worn part can leak more as it degrades.
Why it matters in circuits
Standby and battery life
In battery-powered and standby circuits, leakage can drain a stored charge slowly. A capacitor that holds a backup voltage for a clock or a memory chip may discharge sooner than expected if its leakage is high.
Timing, sample-and-hold and high-impedance inputs
Timing and sample-and-hold circuits rely on a capacitor holding its charge for a set time. Leakage causes the voltage to drift, which shifts the timing or the held value. High-impedance inputs, such as some sensor or measurement front ends, are also sensitive to small leakage currents.
DC offset in coupling stages
A coupling capacitor passes the AC signal while blocking DC. If leakage lets a small DC current through, the bias of the following stage can shift over time, which can affect the signal. This is one reason low-leakage film parts are often chosen for coupling.
How to measure it
Leakage is measured with a DC supply, a sensitive ammeter in series, and a set settle time at the test voltage. Some labs use an insulation resistance tester. A basic multimeter is not suitable for leakage measurement, because its input and test currents are too coarse for the very small values involved.
Discharge the capacitor before connecting it to a test setup, and keep to the voltage limits of the part.
Key takeaways
- Leakage current is a small DC current that flows through the dielectric when a voltage is applied.
- It can be modeled as a high insulation resistance in parallel with the capacitor.
- Electrolytic and tantalum parts leak more than ceramic and film parts.
- Leakage matters in standby, timing, sample-and-hold, high-impedance and coupling circuits.
- Check the datasheet for the part’s leakage figure, and do not expect a basic multimeter to measure it.